New product of liquid silicon balata and treatment are controlled
- Time:
- Click:156
2600 tests. Sample passed the strict test that perhaps opposes Fu and the product that food contacts for a long time. Because have,store longerly life, balata of odd constituent silicon can be supplied with the means that cooperates completely. The existence when this decreased to mix deserves to compare undeserved possibility. Odd constituent is supplied after silicon balata is OK and chromatic, do not need to resemble balata of double constituent silicon adding colorant to mix before mould pressing shapes euqally. Accordingly, simple pump can replace existing mixed juice to measure equipment. Inject of balata of Nextpage liquid silicon shapes because the viscosity of LSR is inferior,control, shape in inject in the process, although be below the circumstance with inject inferior pressure, fill velocity of flow also can be compared fast. The cycle time of contemporary LSR fast vulcanization is shorter (the cycle time below certain circumstance is less than 20 seconds) , to make full use of this one character, forming machine of treatment machinery, inject and component move system must cooperate each other, as a height compositive whole is run. Cold flow path shapes the serious treatment that cold flow path shapes is balata of liquid state silicon is special one of a note of the ancient Chinese five-tone scale. The device of cold flow path that uses at present has two kinds of basic kinds, close namely system and open system, they have actor drawback each. Compare with vented system photograph, close the characteristic with the most typical system is undertake noting model below inferior inject pressure. In equipment adjustable accuse " reduce expenditure mouth " can be opposite of lopsided runner and stock different cut wind shear rare function to undertake fine tuning. Defect is right certain the part that gives size and mould, equipment needs additional adjustment. Open system is used through nozzle or of valve tall cut rate, when inject pressure is reduced, undertake cut flows. Usually, the cavity fill time of open system should be compared close system a little a few shorter. Open system because runner and nozzle are lesser, cavity density is higher. Runner asks to be balanced naturally, and with stock itself shed denaturation to be able to match strictly. Because the flow path dimension of open system is lesser, so normally need not adjustable " reduce expenditure mouth " , need common valve to be able to control flow well only, gain first-rate pressure point. Because LSR viscosity is low,distribute modular line, must ensure the accuracy of the molded lines that distribute a model, avoid occurrence Mao Bian. The geometrical appearance of the component and the position of the line that distribute a model still can affect velar process. In component design, slight root is cut conduce to ensure by model stably union is together between component and mould cavity. Although liquid silicon balata shapes in inject,contract did not contract in the process, but because silicon balata has more expensive hot coefficient of expansion, connect regular meeting to have the systole of 2%-3% after taking off film, refrigeration consequently. Exact contractive data basically depends on stock recipe, but in light of the viewpoint from treatment, if the architect is being conceived when, if a few elements that contract to the influence beforehand consider somewhat, last contractive case can change somewhat, the temperature that these elements basically include to machine, stock takes off pressure of velar temperature, cavity to wait. Exhaust eliminates the optimal method that cavity sluggish leave a blank enrages, it is in each inject shapes in the loop, the method that uses vacuumize will stay in air to drive away in cavity. That is to say, ensure when the design distributes modular line the mould is airtight, vavuum pump passes the clamping apparatus below mould switch to have place cavity vacuumize. Once vacuum is spent,achieve expect standard requirement, shut a mould immediately, begin injection. The method that still has a kind of success application is, use adjust clamping apparatus strength is achieved drive away airy purpose. Maker comes in fill of the LSR when clamping apparatus force is inferior the 90%-95% of cavity, increase clamping apparatus strength again later, avoid balata of silicon of liquid of keep long in stock to spill over at the same time, produce Mao Bian. If sprue uses system of cold flow path, it is very important that effective segregation temperature is installed between hot cavity and cold flow path. If runner is too hot, stock begins solidify before inject, and if refrigeration is too fast, it can absorb overmuch quantity of heat from mould valve area, prevent hindering solidify finish. Close systematic valve or it is actuate is sold, general design is 0.
5-0.
Between 8mm, with assuring the mobile space of the stock that sell and flows all round it. And in vented system, nozzle and valve want normally a few smaller (0.
2-0.
5mm) , so OK better control flow. In addition, drawing of patterns of design of mould material, structure, adiabatic design, goods is the element that needs integrated consideration. CNC Milling